%27%20fill-opacity%3D%27.5%27%3E%3Cpath%20fill%3D%22%233a0000%22%20fill-opacity%3D%22.5%22%20d%3D%22M883.8%2052.7L597%201145.4%20293.2%20132.9z%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(-69.94229%201071.27313%20-199.1637%20-13.00319%20114.7%20537.7)%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(200.62466%2025.2716%20-134.44788%201067.34674%201035.6%20678.7)%22%2F%3E%3Cellipse%20fill%3D%22%2368183a%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(-63.4877%20428.39778%20-217.8944%20-32.29152%20594%20551.1)%22%2F%3E%3C%2Fg%3E%3C%2Fsvg%3E)
%27%20fill-opacity%3D%27.5%27%3E%3Cellipse%20fill%3D%22%23545454%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(46.37314%20.22996%20-.59178%20119.33819%20156.5%20197.8)%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22rotate(-177%2022.5%2056.9)%20scale(52.20604%20298.82812)%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22rotate(-98%20204.6%20-41.8)%20scale(278.38916%2058.74211)%22%2F%3E%3Cellipse%20fill%3D%22%23a4a4a4%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(33.28834%20-36.14566%2039.79678%2036.65084%20154.8%20103.8)%22%2F%3E%3C%2Fg%3E%3C%2Fsvg%3E)
High voltage tester 60kV 350mA
Read moreTECHNICAL DATA:(High voltage tester)
Input power supply for HV voltage source:415V AC, +/- 10%, 3 phase ,50Hz
Input power supply for control unit: 230V AC, +/- 10%, 1 phase, 50Hz
Input current for HV voltage source:75A , 2 phase
Rated Capacity: 30KVA
Range – (0-60KV)
Voltage accuracy – +/-2% of reading +/- 1 digit for KV
Output current – 1mA- 300mA
Current accuracy – +/-2% of reading +/- 1 digit for mA
Dielectric test on HV: 70 kV for 1 min withstand
Dielectric test between :20 kV for 1 min withstand
Transformer type: Dry resin cast type
Control unit dimension: 140cm H x 63 cm L x 56 cm W
Transformer unit dimension: 150cm H x 100cm L x 75 cm W
Enclosure: Housed in powder coated (ral 7035)
Test time setting: Adjustable
Parameter setting: Arrangement for setting voltage, leakage current limit
and timer to apply voltage.We can deliver the product up to your nearest transport office.
Quick View%27%20fill-opacity%3D%27.5%27%3E%3Cpath%20fill%3D%22%233a0000%22%20fill-opacity%3D%22.5%22%20d%3D%22M883.8%2052.7L597%201145.4%20293.2%20132.9z%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(-69.94229%201071.27313%20-199.1637%20-13.00319%20114.7%20537.7)%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(200.62466%2025.2716%20-134.44788%201067.34674%201035.6%20678.7)%22%2F%3E%3Cellipse%20fill%3D%22%2368183a%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(-63.4877%20428.39778%20-217.8944%20-32.29152%20594%20551.1)%22%2F%3E%3C%2Fg%3E%3C%2Fsvg%3E)
%27%20fill-opacity%3D%27.5%27%3E%3Cellipse%20fill%3D%22%23545454%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(46.37314%20.22996%20-.59178%20119.33819%20156.5%20197.8)%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22rotate(-177%2022.5%2056.9)%20scale(52.20604%20298.82812)%22%2F%3E%3Cellipse%20fill%3D%22%23fff%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22rotate(-98%20204.6%20-41.8)%20scale(278.38916%2058.74211)%22%2F%3E%3Cellipse%20fill%3D%22%23a4a4a4%22%20fill-opacity%3D%22.5%22%20rx%3D%221%22%20ry%3D%221%22%20transform%3D%22matrix(33.28834%20-36.14566%2039.79678%2036.65084%20154.8%20103.8)%22%2F%3E%3C%2Fg%3E%3C%2Fsvg%3E)
High voltage tester 70kV 350mA
Read moreTECHNICAL DATA:(High voltage tester)
Input power supply for HV voltage source:415V AC, +/- 10%, 3 phase ,50Hz
Input power supply for control unit: 230V AC, +/- 10%, 1 phase, 50Hz
Input current for HV voltage source:75A , 2 phase
Rated Capacity: 30KVA
Range – (0-100KV)
Voltage accuracy – +/-2% of reading +/- 1 digit for KV
Output current – 1mA- 300mA
Current accuracy – +/-2% of reading +/- 1 digit for mA
Dielectric test on HV: 110 kV for 1 min withstand
Dielectric test between :20 kV for 1 min withstand
Transformer type: Dry resin cast type
Control unit dimension: 140cm H x 63 cm L x 56 cm W
Transformer unit dimension: 150cm H x 100cm L x 75 cm W
Enclosure: Housed in powder coated (ral 7035)
Test time setting: Adjustable
Parameter setting: Arrangement for setting voltage, leakage current limit
and timer to apply voltage.We can deliver the product up to your nearest transport office.
Quick View
Loading...All products loaded